Browsing from:

Allen Bradley ControlLogix Communication Modules

Communication Modules

Available options include EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, Foundation Fieldbus, Serial, DH-485, and SynchLink. Multiple communication modules can be installed in the ControlLogix system to allow control and/or sharing of data over different networks.

After determining the networks you will be using you will be able to select the communication modules your system will require and the necessary cables and network equipment. Remember to plan for extra modules and cables if you are designing a redundant system. It is possible to route a message through up to 4 different chassis (8 communication hops). A ControlLogix controller is not required in each chassis to accomplish this. The following tables list the various communication modules available to interface with your system. The first table lists normal usage applications for the industry protocol communications networks.

Communication Network Applications

Communication Network Standard Applications
EtherNet/IP Plant Management (Material Handling)
Configuration,Data Collection & Control/Single High Speed Network
Time Critical Applications/No Established Schedule
Inclusion of Commercial Technologies (Video over IP, etc.)
Internet/Intranet Connection
Integrated CIP Motion & Safety
ControlNet High Speed Transfer of Time Critical Data Between Controllers and I/O Devices
Deterministic & Repeatable Data Delivery
Media Redundancy
Intrinsic Safety
Redundant Controller Systems
DeviceNet Connection of Low-Level Devices to Controllers w/o Interfacing Through I/O Modules
Data Sent As Needed
More Diagnostics for Improved Data Collection & Fault Detection
Less Wiring & Reduced Start-Up Time than Traditional Hard-Wired System
Data Highway Plus Plant Wide and Cell Level Data Sharing With Program Maintenance
Data Sent on Regular Basis
Transferring Information Between Controllers
Remote I/O Connections Between Controllers & I/O Adapters
Data Sent on Regular Basis
Distributed Control/Each Controller Has I/O & Communicates with Supervisory Controller
Foundation Fieldbus Fieldbus Transmitters & Actuators
Closed Loop Control
Process Automation

EtherNet/IP Communication Modules

The EtherNet Industrial Protocol Network (EtherNet/IP) is an industry standard open network which supports both real time input/output messaging and message exchange. EtherNet/IP uses readily available standard EtherNet communication chips and/or physical media.

Part Number EtherNet/IP
Application
Media Communication
Rate
CIP Motion
Axes (Max)
TCP/IP
Connections
Logix
Connections
1756-EN2F  Bridge, Fiber Fiber 100 Mbps 8 128 256
1756-EN2T  Bridge, Copper Copper 10/100 Mbps 8 128 256
1756-EN2TR Bridge, Copper,
Embedded Switch
Dual Copper 10/100 Mbps 8 128 256
1756-EN3TR Bridge, Copper,
Embedded Switch
Dual Copper 10/100 Mbps 128 128 256
1756-ENBT Bridge, Copper Copper 10/100 Mbps 64 128
1756-EWEB Web Server Module Copper 10/100 Mbps 64 128
1756-EN2TXT ControlLogix-XT Bridge, Copper, Extreme Environments Copper 10/100 Mbps 8 128 256

EtherNet/IP Network Accessories

Part Number EtherNet/IP Application Specifications
1585J-M8PBJM-x RJ45 Patchcord; x = 2 (2m), x = 5 (5m),
or x = 10 (10m)
8 Conductor, Teal Riser PVC Cable
(Flex Rated Cable Available)
1585J-M8CC-H RJ45 Insulation Displacement
Connector (IDC)
0.128... 0.325 mm2  (26... 22 AWG), Cat. 6,
IDC, No Tool Required
1585J-M8CC-C RJ45 Crimp Connector With Boot,
Quantity: 50 Pieces
0.128... 0.205 mm2 (26... 24 AWG), Cat 5e,
Crimp Tool Required
1585Jcrimp Crimp Tool Use With 1585J-M8CC-C
9300-RADES Remote Access Dial-In Kit 56 Kbps Modem Connection With:
Pre-Configured Modem,
Communication Module,
DIN Rail Mounting Hardware,
and Associated Cables

ControlNet Communication Modules

The ControlNet network provides high speed capabilities by combining the best aspects of an input/output network and a peer-to-peer network. ControlNet features deterministic, repeatable transfers of critical control data. The modules with 128 Logix connections also have an additional 3 connections reserved for redundant control. For the modules with 64 Logix connections it is recommended to use only 40 to 48 of these for input/output connections.

Part Number ControlNet
Application
Communication
Rate
Logix
Connections
Number
of Nodes
1756-CN2/B Standard Media Bridge 5 Mbps 128 (+3) 99
1756-CN2R/B Redundant Media Bridge 5 Mbps 128 (+3) 99
1756-CNB Standard Media Bridge 5 Mbps 64 99
1756-CNBR Redundant Media Bridge 5 Mbps 64 99
1756-CN2RXT ControlLogix-XT Redundant Media Bridge 5 Mbps 128 (+3) 99

DeviceNet Communication Module and Accessories

The DeviceNet network, as its name implies, provides communication connections between system devices. The devices can be as simple as sensors and actuators or more complex devices, such as controllers and computers.

Part Number DeviceNet Application
1756-DNB DeviceNet Bridge Module
Communication Rates: 125 Kbps (500 m max); 250 Kbps (250 m max);
500 Kbps (100 m max)
Number of Nodes: 64
KwikLink Lite Flat Media Newer, ODVA approved for wiring DeviceNet networks. Supports intermixing of  DeviceNet cable types, such as round with flat. KwikLink Lite connectors provide insulation displacement.
KwikLink Flat Media Modular cabling with flat 4-wire cable and insulation displacement connectors (IDCs). System Nodes can be added without cutting or stripping trunkline. Eliminates need for predetermined cable lengths.
Round Media Round trunk cable is available in bulk spools or as pre-molded cable sets of various lengths. Round cable supports rugged and durable DeviceNet components, including stainless steel versions:
1. Thick trunk round cable provides maximum length DeviceNet trunk lines.
2. Thin trunk cable reduces maximum trunk line distances with a more compact installation. Thin cable outer jacket is TPE for added chemical resistance.

Data Highway Plus and Remote Input/Output Communication Modules and Accessories

Part Number Description Communication
Rate
DH+
Connections
RIO
Connections
Logix
Connections
1756-DHRIO DH+/Remote I/O 57.6 Kbps, 115.2 Kbps, 230.4 Kbps 32 DH+ messages per DH+ Module Remote I/O Scanner:
32 logical rack /channel;
16 block-transfer/channel
32
1756-RIO Remote I/O 57.6 Kbps, 115.2 Kbps, 230.4 Kbps -- Remote I/O Scanner/Adapter:
32 physical racks (0... 76), any rack size and/or block transfers
10 Scheduled
Input/Output
1756-DHRIOXT Extended Temperature
DH+/Remote I/O
57.6 Kbps, 115.2 Kbps, 230.4 Kbps 32 DH+ messages per DH+ Module Remote I/O Scanner:
32 logical rack/channel;
16 block-transfer/channel
32
1770-CD Belden 9463 twin axial cable; connects communication module to DH+ Network
9300-RADKIT Remote access dial-in kit: 56 Kbps modem connection to DH+ Network devices. Kit includes: Pre-configured Modem, Communication Module, DIN rail mounting hardware, and associated cables.

FOUNDATION Fieldbus Linking Devices

FOUNDATION Fieldbus networks are designed for distributed control of process applications. The Fieldbus network is linked to other plant networks with the following bridge devices. Although these linking devices can accommodate up to 16 devices per H1 link, 8 to 10 devices per link is recommended.

Part Number Fieldbus
Application
Communication
Rate
H1 Ports Devices per
H1 Link
Total Device Links
Available
1757FFLD2 EtherNet/IP
Network Bridge
Fieldbus: 31.25 Kbps
EtherNet/IP: 10/100 Mbps
2 16 32
1757-FFLD4 EtherNet/IP
Network Bridge
Fieldbus: 31.25 Kbps
EtherNet/IP: 10/100 Mbps
4 16 64
1757-FFLDC2  ControlNet
Network Bridge
Fieldbus: 31.25 Kbps
ControlNet: 5 Mbps
2 16 32
1757-FFLDC4  ControlNet
Network Bridge
Fieldbus: 31.25 Kbps
ControlNet: 5 Mbps
4 16 64
PLC Parts

PLC Parts

Supplier of PLC Parts for:

GE Fanuc
Allen-Bradley